Pump Seal Changeouts and Repacking
The shaft seal is the most common place for a centrifugal pump to fail, and the easiest failure to prevent. Chas G. Allen, Inc. replaces mechanical seals and gland packing on the pumps that power generation and heavy industry rely on, on site or in our Barre, Massachusetts shop. We also look at why the old seal failed, so the new one lasts.
What a Shaft Seal Does
Where the pump shaft passes from the wet end out to atmosphere, a seal keeps process fluid in and contamination out. There are two common designs:
- Gland packing: rings of compressed packing around the shaft, designed to allow a small, controlled leak that cools and lubricates the packing.
- Mechanical seals: two precisely lapped faces, one rotating and one stationary, running on a thin fluid film. They leak far less than packing but are less forgiving of poor operating conditions.
Signs a Seal Changeout Is Due
- Leakage at the seal or stuffing box that keeps increasing
- Packing that can no longer be adjusted to an acceptable leak rate
- Heat, smoking or scoring at the seal area
- Process fluid contaminating the bearing housing
What Causes Seals to Fail
A worn seal is usually a symptom, not the root problem. Misalignment, vibration, dry running, operating far from the pump’s best efficiency point, or a seal that isn’t suited to the fluid and operating conditions will all shorten seal life. Replacing the seal without addressing the cause brings the leak back.
That’s why seal changeouts often go hand in hand with laser alignment and dynamic balancing.
Our Seal Changeout Service
- Removal and replacement of mechanical seals or gland packing
- Seal selection matched to your pump model and operating conditions
- Failure analysis of the removed seal
- Seal upgrades where the original design is the problem
- Routine maintenance or emergency repair, at your plant or in our shop
Seeing a Leak at the Seal?
Contact us to schedule a seal changeout or to talk through a recurring seal failure.